Order Code RPRT3 Rapid Plasma Reagin (RPR) with Reflex to Treponema pallidum Particle Agglutination, Serum

Important Note

This test should only be ordered on positive patients to monitor treatment.

The initial screening test should be ordered as the Syphillis IgG Ab performed in the Waterloo lab. If the Syphillis ab is reactive the RPR will be sent to Mayo by the lab as a confirmation of antibody results.

Additional Codes

Epic IMO4277ia


Ordering Guidance


This assay should only be used following an initial reactive treponemal antibody assay result as part of the reverse syphilis testing algorithm.



Specimen Required


Supplies: Sarstedt Aliquot Tube, 5 mL (T914)

Collection Container/Tube:

Preferred: Serum gel

Acceptable: Red top

Submission Container/Tube: Plastic vial

Specimen Volume: 0.3 mL

Collection Instructions: Centrifuge and aliquot serum into a plastic vial.


Secondary ID

616970

Useful For

Diagnosing syphilis

Reflex Tests

Test ID Reporting Name Available Separately Always Performed
RPRT4 RPR, Titer, S No No
RTPPA Syphilis Ab, TP-PA, S Yes, (Order TPPA) No

Testing Algorithm

If this test is positive, then the rapid plasma reagin titer will be performed at an additional charge.

 

If this test is negative, then the Treponema pallidum particle agglutination test will be performed at an additional charge.

 

For more information see Syphilis Serology Algorithm.

Special Instructions

Method Name

RPRT3, RPRT4: Flocculation/Agglutination

RTPPA: Particle Agglutination

Reporting Name

RPR w/ Reflex to TP-PA, S

Specimen Type

Serum

Specimen Minimum Volume

See Specimen Required

Specimen Stability Information

Specimen Type Temperature Time
Serum Refrigerated (preferred) 14 days
  Frozen  14 days

Reject Due To

Gross hemolysis Reject
Gross lipemia Reject

Clinical Information

Syphilis is caused by infection with the spirochete Treponema pallidum subspecies pallidum. The infection is systemic, and the disease is characterized by periods of latency. These features, together with the fact that T pallidum cannot be isolated in culture, mean that serologic techniques play a major role in the diagnosis and follow-up of treatment for syphilis.

 

Historically, the serologic testing algorithm for syphilis included an initial nontreponemal screening test, such as the rapid plasma reagin (RPR) or the VDRL tests. Because these tests measure the host's immune response to nontreponemal antigens, they lack specificity. Therefore, a positive result by RPR or VDRL requires confirmation by a treponemal-specific test, such as the fluorescent treponemal antibody-absorption (FTA-ABS) or microhemagglutination (MHA-TP) assay. Although the FTA-ABS and MHA-TP assays are technically simple to perform, they are labor intensive and require subjective interpretation by testing personnel.

 

As an alternative to the traditional syphilis screening algorithm, many laboratories utilize the reverse syphilis screening algorithm. This algorithm starts with an automated treponemal assay to detect antibodies specific to T pallidum. If this screening assay is positive, the sample is reflexed for testing by RPR, which, if positive, is reported with a titer and is indicative of active or recent syphilis infection. If the RPR is negative, the sample is reflexed to a second treponemal assay, such as the T pallidum particle agglutination (TP-PA) assay. If the TP-PA is positive, this would indicate previously treated or late-stage syphilis infection. Alternatively, if the TP-PA is negative, the initial positive screen is interpreted as a false positive result.

 

Patients with primary or secondary syphilis are typically tested by RPR to their monitor response to treatment. Typically, RPR titers decrease following successful treatment, but this may occur over a period of months to years. Additionally, testing of maternal and neonate serum, collected concurrently, by RPR can be used as an aid to diagnose congenital syphilis.

Reference Values

Negative

 

Reference values apply to all ages.

Clinical Reference

1. Tuddenham S, Katz SS, Ghanem KG. Syphilis Laboratory Guidelines: Performance characteristics of nontreponemal antibody tests. Clin Infect Dis. 2020;71(Suppl 1):S21-S42. doi:10.1093/cid/ciaa306

2. Park IU, Tran A, Pereira L, Fakile Y. Sensitivity and specificity of treponemal-specific tests for the diagnosis of syphilis. Clin Infect Dis. 2020;71(Suppl 1):S13-S20. doi:10.1093/cid/ciaa349

3. Theel ES, Katz SS, Pillay A. Molecular and direct detection tests for Treponema pallidum subspecies pallidum: A review of the literature, 1964-2017. Clin Infect Dis. 2020;71(Suppl 1):S4-S12. doi:10.1093/cid/ciaa176

4. Ortiz DA, Shukla MR, Loeffelholz MJ. The traditional or reverse algorithm for diagnosis of syphilis: Pros and cons. Clin Infect Dis. 2020;71(Suppl 1):S43-S51. doi:10.1093/cid/ciaa307

Day(s) Performed

Monday through Saturday

Report Available

Same day/1 to 4 days

Performing Laboratory

Mayo Clinic Laboratories in Rochester

Test Classification

This test has been cleared, approved, or is exempt by the US Food and Drug Administration and is used per manufacturer's instructions. Performance characteristics were verified by Mayo Clinic in a manner consistent with CLIA requirements.

CPT Code Information

86592

86593- (if appropriate)

86780- (if appropriate)

LOINC Code Information

Test ID Test Order Name Order LOINC Value
RPRT3 RPR w/ Reflex to TP-PA, S 20507-0

 

Result ID Test Result Name Result LOINC Value
616970 RPR w/ Reflex to TP-PA, S 20507-0

Forms

If not ordering electronically, complete, print, and send an Infectious Disease Serology Test Request (T916) with the specimen.